Section available in PDF format. Click here to view... |
Earth Leakage Relays - We design and manufacture a number of multi function Earth Leakage Relays:
earth leakage relay; earth fault relay; ground fault relay;ground fault protection; core balance transformer; toroids.
These Earth Leakage Relays are supplied with various mountings:- The ELRM44 series with DIN rail mounting
- The ELRP48 series 48 x 48 Panel mounting
- The ELRV series DIN rail mounting
- The ELR-IF series either DIN rail or surface mounting
- The ELRF series with with DIN rail mounting
- The Circular and Rectangular Toroid series
See below for our complete range of Earth Leakage Relay products.
| | Display: [All | New | Home] Scroll to right to see all products. Click in title area to view PDF file if available. |
| ELRM44 Series DIN Rail Mtg |
Click to enlarge
ELRM44V-30
Click to enlarge
ELRM44F
DIMS: (mm) H.85 W.44 D63.5
|
| Type No |
 |
ELRM44V-30 |
 |
|
 |
ELRM44F-0300 |
 |
|
 |
ELRM44F-0100 |
 |
|
 |
ELRM44F-0030 |
 |
|
| Description |
Earth Leakage Relay |
Earth Leakage Relay |
Earth Leakage Relay |
Earth Leakage Relay |
| Function |
Variable - Type A (True R.M.S.) |
Fixed - Type A (True R.M.S.) |
Fixed - Type A (True R.M.S.) |
Fixed - Type A (True R.M.S.) |
| Supply voltage Un |
12 - 125V DC, 24, 115/230V, 400VAC 50/60Hz |
12 - 125V DC, 24, 115/230V, 400VAC 50/60Hz |
12 - 125V DC, 24, 115/230V, 400VAC 50/60Hz |
12 - 125V DC, 24, 115/230V, 400VAC 50/60Hz |
| Sensitivity IDn |
30, 100, 300, 500mA, 1, 3, 5, 10, 20, 30A (selectable) |
300mA |
100mA |
30mA |
| Range |
0 - 30A |
- |
- |
- |
| Time delay |
inst., 0.06, 0.15, 0.25, 0.5, 0.8, 1, 2.5, 5, 10sec. (selectable) |
inst. (<25mS when fault current @ 5 x IDn) |
inst. (<25mS when fault current @ 5 x IDn) |
inst. (<25mS when fault current @ 5 x IDn) |
| LED indication |
Power On indication (Green) |
Power On indication (Green) |
Power On indication (Green) |
Power On indication (Green) |
| |
Tripped indication (Red) - LED flashes during toroid open circuit |
Tripped indication (Red) - LED flashes during toroid open circuit |
Tripped indication (Red) - LED flashes during toroid open circuit |
Tripped indication (Red) - LED flashes during toroid open circuit |
| |
LED Bargraph showing leakage current (25, 50 and 75% of IDn) |
- |
- |
- |
| Test/Reset facility |
Local and Remote |
Local and Remote |
Local and Remote |
Local and Remote |
| Output |
1 x SPDT (S.O.)/ 1 x SPNO (P.S.O.) |
1 x SPDT (S.O.) |
1 x SPDT (S.O.) |
1 x SPDT (S.O.) |
| Output rating |
8A @ 250VAC (AC1) - S.O. 6A @ 250V AC (AC1) - P.S.O. |
8A @ 250VAC (AC1) |
8A @ 250VAC (AC1) |
8A @ 250VAC (AC1) |
| 50% Fault level output |
- |
- |
- |
- |
| Adjustment cover and tamperproof seal |
Yes |
No |
No |
No |
| Ratio |
- |
- |
- |
- |
| Internal Dimension |
- |
- |
- |
- |
| External Dimensions in mm |
- |
- |
- |
- |
|
| ELRP48 Series 48 x 48 Panel mounting |
Click to enlarge
ELRP48V-30 DIMS: (mm) H.48 W.48 D.76* (*behind panel)
|
| Type No |
 |
ELRP48V-30 |
 |
|
| Description |
Earth Leakage Relay |
| Function |
Variable - Type A (True R.M.S.) |
| Supply voltage Un |
12 - 125V DC, 24, 115V, 230V 50/60Hz |
| Sensitivity IDn |
30, 100, 300, 500mA, 1, 3, 5, 10, 20, 30A (selectable) |
| Range |
0 - 30A |
| Time delay |
inst., 0.06, 0.15, 0.25, 0.5, 0.8, 1, 2.5, 5, 10sec. (selectable) |
| LED indication |
Power On indication (Green) |
| |
Tripped indication (Red) - LED flashes during toroid open circuit |
| |
LED Bargraph showing leakage current (25, 50 and 75% of IDn) |
| Test/Reset facility |
Local and Remote |
| Output |
1 x SPDT (S.O.)/ 1 x SPNO (P.S.O.) |
| Output rating |
8A @ 250VAC (AC1) - S.O., 6A @ 250V AC (AC1) - P.S.O. |
| 50% Fault level output |
- |
| Adjustment cover and tamperproof seal |
Yes |
| Ratio |
- |
| Internal Dimension |
- |
| External Dimensions in mm |
- |
|
| ELRV Series DIN Rail Mtg |
Click to enlarge
ELRV-10
Click to enlarge
ELRV-30
DIMS: (mm) H.85 W.70 D.63.5
|
| Type No |
 |
ELRV-30 |
 |
|
| ELRV-10 |
 |
|
| Description |
Earth Leakage Relay |
Earth Leakage Relay |
| Function |
Variable - Type A (True R.M.S.) |
Variable - Type A |
| Supply voltage Un |
10 - 60V DC 24, 115, 230, 400V AC 50/60Hz |
220/240V AC 50/60Hz |
| Sensitivity IDn |
18 settings ranging from 6mA to 30A |
30, 50, 75, 100mA (selectable) |
| Range |
mA and Amps |
x1, x10, x100 (selectable) |
| Time delay |
8 settings ranging from inst. to 10 seconds |
inst., 50, 250, 500mS |
| LED indication |
Tripped indication |
Tripped indication |
| |
LED display for indicating user |
Bargraph indicating |
| |
settings and leakage current |
% leakage current |
| Test/Reset facility |
Local and Remote |
Local and Remote |
| Output |
2 x SPDT Relays |
2 x SPDT Relays |
| Output rating |
8A @ 250VAC (AC1) |
8A @ 250V AC |
| 50% Fault level output |
10W max. up to 240V max. |
10W max. @ Un |
| Adjustment cover and tamperproof seal |
Yes |
Yes |
| Ratio |
- |
- |
| Internal Dimension |
- |
Now Discontinued |
| External Dimensions in mm |
- |
See ELRM44V-30 or ELRV-30 |
|
| ELR-IF Series DIN Rail & Surface Mtg |
Click to enlarge
ELR-IF DIMS: (mm) H.110 W.70 D.37
|
| Type No |
 |
ELR-IF-0300 |
 |
|
 |
ELR-IF-0100 |
 |
|
 |
ELR-IF-0030 |
 |
|
| Description |
Earth Leakage Relay with Internal Toroid |
Earth Leakage Relay with Internal Toroid |
Earth Leakage Relay with Internal Toroid |
| Function |
Fixed - Type A (True R.M.S.) |
Fixed - Type A (True R.M.S.) |
Fixed - Type A (True R.M.S.) |
| Supply voltage Un |
120V, 240V AC 50/60Hz |
120V, 240V AC 50/60Hz |
120V, 240V AC 50/60Hz |
| Sensitivity IDn |
300mA |
100mA |
30mA |
| Range |
- |
- |
- |
| Time delay |
100mS |
100mS |
inst. (<25mS when fault current @ 5 x IDn) |
| LED indication |
Power On indication (Green) |
Power On indication (Green) |
Power On indication (Green) |
| |
Tripped indication (Red) - LED flashes if fault current >50% of IDn |
Tripped indication (Red) - LED flashes if fault current >50% of IDn |
Tripped indication (Red) - LED flashes if fault current >50% of IDn |
| |
- |
- |
- |
| Test/Reset facility |
Local only |
Local only |
Local only |
| Output |
1 x SPDT (S.O.) |
1 x SPDT (S.O.) |
1 x SPDT (S.O.) |
| Output rating |
5A @ 250VAC (AC1) |
5A @ 250VAC (AC1) |
5A @ 250VAC (AC1) |
| 50% Fault level output |
- |
- |
- |
| Adjustment cover and tamperproof seal |
No |
No |
No |
| Ratio |
- |
- |
- |
| Internal Dimension |
25mm dia. intergral toroid |
25mm dia. intergral toroid |
25mm dia. intergral toroid |
| External Dimensions in mm |
- |
- |
- |
|
| ELRF Series DIN Rail Mtg |
Click to enlarge
DIMS: (mm) H.85 W.70 D.63.5
|
| Type No |
| ELRF0300 |
 |
|
| ELRF0100 |
 |
|
| ELRF0030 |
 |
|
| Description |
Earth Leakage Relay |
Earth Leakage Relay |
Earth Leakage Relay |
| Function |
Fixed - Type A |
Fixed - Type A |
Fixed - Type A |
| Supply voltage Un |
110/115V, 220/240V AC 50/60Hz |
110/115V, 220/240V AC 50/60Hz |
110/115V, 220/240V AC 50/60Hz |
| Sensitivity IDn |
300mA |
100mA |
30mA |
| Range |
- |
- |
- |
| Time delay |
inst. |
inst. |
inst. |
| LED indication |
Tripped indication |
Tripped indication |
Tripped indication |
| |
- |
- |
- |
| |
- |
- |
- |
| Test/Reset facility |
Local only |
Local only |
Local only |
| Output |
SPDT Relay |
SPDT Relay |
SPDT Relay |
| Output rating |
8A @ 250V AC |
8A @ 250V AC |
8A @ 250V AC |
| 50% Fault level output |
- |
- |
- |
| Adjustment cover and tamperproof seal |
No |
No |
No |
| Ratio |
- |
- |
- |
| Internal Dimension |
Now Discontinued |
Now Discontinued |
Now Discontinued |
| External Dimensions in mm |
See ELRM44F-0300 |
See ELRM44F-0100 |
See ELRM44F-0030 |
|
| Circular and Rectangular Toroid |
Click to enlarge
BZCT Circular Toroids
Click to enlarge
BZCTR Rectangular Toroids
|
| Type No |
 |
BZCT035 |
 |
|
 |
BZCT070 |
 |
|
 |
BZCT120 |
 |
|
 |
BZCT210 |
 |
|
 |
BZCTR115 |
 |
|
 |
BZCTR150 |
 |
|
| Description |
Circular Toroid 35mm |
Circular Toroid 70mm |
Circular Toroid 120mm |
Circular Toroid 210mm |
Rectangular Toroid 115mm |
Rectangular Toroid 150mm |
| Function |
35mm Toroid |
70mm Toroid |
120mm Toroid |
210mm Toroid |
115 x 305mm Toroid |
150 x 350mm Toroid |
| Supply voltage Un |
- |
- |
- |
- |
- |
- |
| Sensitivity IDn |
- |
- |
ELR IDn trip setting must be >100mA |
ELR IDn trip setting must be >300mA |
- |
- |
| Range |
- |
- |
- |
- |
- |
- |
| Time delay |
- |
- |
- |
- |
- |
- |
| LED indication |
- |
- |
- |
- |
- |
- |
| |
- |
- |
- |
- |
- |
- |
| |
- |
- |
- |
- |
- |
- |
| Test/Reset facility |
- |
- |
- |
- |
- |
- |
| Output |
- |
- |
- |
- |
- |
- |
| Output rating |
- |
- |
- |
- |
- |
- |
| 50% Fault level output |
- |
- |
- |
- |
- |
- |
| Adjustment cover and tamperproof seal |
- |
- |
- |
- |
- |
- |
| Ratio |
1/1000 |
1/1000 |
1/1000 |
1/1000 |
1/1000 |
1/1000 |
| Internal Dimension |
35mm |
70mm |
120mm |
210mm |
115 x 305mm |
150 x 350mm |
| External Dimensions in mm |
H.74 W.64 D*.40 *inc mounting feet |
H.117 W.105 D*.40 *inc mounting feet |
H.170 W.155 D*.40 *inc mounting feet |
- |
H.240 W.402 D.55 |
H.285 W.460 D.55 |
|
|
|